SR-2304B-WP
Product Data
- In compliance with IEC 62386-101:2014, IEC 62386-102:2014, IEC 62386-207 Ed2
- Built-in DALI-2 interface, DALI DT6 device
- Match all DALI systems in the market
- Manual /automatically DALI address setting
- DALI address digital indicate
- Four channels, can set addresses from one to four
- To work with power repeater to expand output power unlimitedly
- Waterproof grade:IP67
Send Enquiry Now
Input Voltage | 12-36VDC |
Output Current | 4 x 5A |
Output Power | 4x(60-180)W |
Size(LxWxH) | 170x53.4x28mm |
Remarks | Constant voltage |
DALI Consumption | 2mA |
Dimming Range | 0.1%-100% |
Ambient Temperature | -20℃ ~ 50℃ |
Set DALI Address Manually Via Buttons
1.1. Press and hold down any of the two buttons until numeric digital display flashes, then release the button.
1.2. Click any of the two buttons once to select a digit, click again to change the digit until the desired DALI address appears. Click first button to set “tens” position and second button to set “units” position. The address
can be set from 00~63.
1.3. Then press and hold down any of the 2 buttons until the numeric digital display stops flashing to confirm the setting.
Set DALI Address Quantity
1.1. Press and hold down both of the two buttons until numeric digital display flashes, then release the button. 1.2. Click first button to select “1A”, “2A”, “3A” or “4A” which means 1 address, 2 addresses, 3 addresses or 4 addresses. 1.3. Then press and hold down any of the 2 buttons until the numeric digital display stops flashing to confirm the setting. For example, when we set address to 22: When select 1A, all four channels will be the same address 22. When select 2A, channel 1 & 3 will be the same address 22, channel 2 & 4 will be the same address 23. When select 3A, channel 1, 2, 3 will be address 22, 23, 24 respectively, and channel 4 address is also 24. When select 4A, channel 1, 2, 3, 4 will be address 22, 23, 24, 25 respectively. DALI Address Assigned by DALI Masters DALI address can also be assigned by DALI Master controller automatically, please refer to user manuals of compatible DALI Masters for specific operations. PUSH Dimmer Mode While connected with a AC PUSH, the digital display will show “PD” which means Push Dimmer Mode, operations under Push Dimmer Mode are as follows: 4.1. Click the button to switch ON/OFF 4.2. Press and hold down the button to increase or decrease light intensity to desired level and release it, then repeat the operation to adjust light intensity to opposite direction. The dimming range is from 1% to 100%. 4.3. Memory function after power off or power failure enables the device to memorize the status before power off while power on again.
1.1. Press and hold down both of the two buttons until numeric digital display flashes, then release the button. 1.2. Click first button to select “1A”, “2A”, “3A” or “4A” which means 1 address, 2 addresses, 3 addresses or 4 addresses. 1.3. Then press and hold down any of the 2 buttons until the numeric digital display stops flashing to confirm the setting. For example, when we set address to 22: When select 1A, all four channels will be the same address 22. When select 2A, channel 1 & 3 will be the same address 22, channel 2 & 4 will be the same address 23. When select 3A, channel 1, 2, 3 will be address 22, 23, 24 respectively, and channel 4 address is also 24. When select 4A, channel 1, 2, 3, 4 will be address 22, 23, 24, 25 respectively. DALI Address Assigned by DALI Masters DALI address can also be assigned by DALI Master controller automatically, please refer to user manuals of compatible DALI Masters for specific operations. PUSH Dimmer Mode While connected with a AC PUSH, the digital display will show “PD” which means Push Dimmer Mode, operations under Push Dimmer Mode are as follows: 4.1. Click the button to switch ON/OFF 4.2. Press and hold down the button to increase or decrease light intensity to desired level and release it, then repeat the operation to adjust light intensity to opposite direction. The dimming range is from 1% to 100%. 4.3. Memory function after power off or power failure enables the device to memorize the status before power off while power on again.